IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
RUGGEDCOM RX1501
Installation Manual, 05/2020, C79000-G8976-1054-17
All manuals and user guides at all-guides.com
Test
Humidity (Damp
Heat, Cyclic)
IEC 61373
Long Life (Random Vibration)
MIL-STD-810G
6.2 EMC and Environmental Type Tests
Description
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
Vibration
Shock
Bump
Shock
Seismic
Altitude
Certification
Test Levels
Severity
Levels
2 g @ 10-150 Hz
Class 2
30 g @ 11 ms
Class 2
10 g @ 16 ms
Class 1
Category 1 Class B
Method A
Level 2
12192 m (40000 ft)
@ 40 °C, 90 minutes
 
 
 
 