3:HDI
4:Multi-steps
5:Remote communication
6:Keypad potentiometer setup
When F0.02=6,this function is valid.The parameter determines the target given
channel during the PID procures..
Goal-setting value of Process of PID is relative value,100% of preset value is
corresponding to 100% of controlled system's feedback value.
System is always processing for operation according to the relative value (0 ~
100%).Each given and feedback are 100.0% relative to 10.0 V
Code
F9.01
Set the parameter when P9.00=0.
The basic value of this parameter is the feedback value.
Code
F9.02
0:AI1
1:AI2
2:AI1+ AI2
3:HDI
4:Communication
This parameter is used to select PID feedback source.
The given channel and the feedback channel can not coincide,otherwise,PID can not
control effectively.
Name
Keypad PID preset
Name
PID feedback source selection
109
Setting Range
0.0%ÿ^100.0%
0 0.0%0
Setting Range
0ÿ^40 00