5-10
Dimensions
5.3

Installation

Installation Notes

Mounting Cut-Out

• When installing the display observe to ensure an ergonomic operation.
Additionally, ensure that all moving machine components are in sight
of the operator.
• Avoid installation locations exposed to direct sunlight, as the screen
readability is reduced and additional heat development can occur.
• Observe that the LED displays on the front panel are not obstructed.
• Lay all connecting cables in loops and use strain reliefs for all cables.
• Keep a suitably large distance from sources of interference.
For mounting the display proceed as follows:
Loss of degree of protection IP 65!
The front panels of the VDP devices correspond to
degree of protection IP 65. To ensure that this degree of
protection also remains preserved in the mounted status,
DANGER
you have to take appropriate measures:
Remove – as mentioned below – immediately before
mounting the device the paper strip from the seal at
the rear side of the front panel.
Further
depending on the mounting location, e. g. the
stabilization of the mounting frame.
1. Create a mounting cut-out with 8 holes, diameter 5 mm, according to
the illustrations "Mounting dimensions" on the following page.
2. Remove the paper strip from the seal at the rear side of the front
panel.
3. Insert the display from the front into the cut-out. Then insert the
mounting bolts M4 into the drilled holes.
4. Fasten the display by screwing the nuts at the rear side of the
mounting bolts.
VDP 16.1, VDP 40.1 and VDP 60.1
required measures
are
DOK-SUPPL*-VDP16/40/60-PR02-EN-P