Opening Error File - Siemens SINUMERIK 840D sl Commissioning Manual

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Language
Czech
Turkish
Hungarian
Slovakian
Romanian
14.2.9

Opening error file

To enable the "Alarm&Event Service" to read the texts, you must convert them from ".ts"
format into binary format. During this process, files with the same name with the file
extension ".qm" are created in the same directory.
Restart HMI sl. The format is converted only during startup. The result of the conversion is
written to the file "alarmtext_conversion.log". Errors that occur during the conversion, such
as syntax errors in a parameter file, are also written to the file.
Note
The conversion is only carried out if the "*.ts" file is newer than the associated "*.qm" file. To
force a new conversion, the "*.ts" file must be edited. Deletion of the "*.qm" file is not
possible since it is loaded at HMI sl runtime.
Directories
The error files are saved in two directories on the CompactFlash Card.
Directory
/User/sinumerik/hmi/log/alarm_log
/User/sinumerik/hmi/log/action_log
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
14.2 Creating alarm texts via alarm text files
Language code
csy
trk
hun
sky
rom
Error file
alarmtext_conversion.log
crash.log
Configuring alarms
Standard languages
127