SYSTEM SETUP

(1)
Procedure of Reset Operation
STEP1: Assign all required system data to the CPU blade of Main Unit, including the required data for
Remote Unit.
STEP2: Load all License Activation data to the Main Unit.
For details, refer to License Activation Operation Guide.
STEP3: Execute the system data backup to the Flash ROM of CPU blade by CMEC Y=6>0: 0.
STEP4: Save the system data of Main Unit by PCPro.
STEP5: Set the SENSE switch of #0 CPU to "E" (Off-line), and push the RESET switch of #0 CPU.
STEP6: Clear the system memory of Remote Unit by CM00>1.
STEP7: Load the system data saved in STEP4 to all Remote Units using PCPro.
STEP8: Assign the Unit numbers for Remote Unit to each CPU blade of Remote Units by CM0B
Y=000>90.
STEP9: Set the SENSE switch of #0 CPU to "1" (on-line), and push the RESET switch of #0 CPU.
STEP10: Confirm that the link between Main Unit and Remote Unit is established.
If not, connect the Main Unit and Remote Unit by LAN.
– The required system data is copied to each Remote Unit from the Main Unit, and Remote
Units starts.
Page 3-41
Chapter 3 REMOTE UNIT OVER IP FEATURES
[For other than North America]
3-21
SYSTEM SETUP
NWA-088654-001 Rev.1.0