Description
● No. of Signaled Faults
Indicates how often the fault LED lit up and not how many faults occurred.
● Reset Counters button
The number is reset with this button. The counter is reset when there is a restart.
The table contains the following columns:
● Fault Time
Shows the time the device has been running since the last system restart when the
described error/fault occurred.
● Fault Description
Displays a brief description of the fault/error that has occurred.
● Clear Fault State
Some faults can be acknowledged and thus removed from the fault list, e.g. a fault of the
event "Cold/Warm Start". If the "Clear Fault State" button is enabled, you can delete the
error.
4.4.7

DHCP Server

This page shows which IPv4 addresses were assigned to the devices by the DHCP server.
Description of the displayed values
● IP Address
Shows the IPv4 address assigned to the DHCP client.
● Pool ID
Shows the number of the IPv4 address band.
● Identification Method
Shows the method with which the DHCP client is identified.
– Remote ID
– Circuit ID
– DUID
● Identification Value
Shows the value that is assigned to the identification method.
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
Shows the remote ID of the DHCP client.
Shows the circuit ID of the DHCP client.
Shows the DUID of the DHCP client.
Configuring with Web Based Management
4.4 "Information" menu
93