Measuring variants

3.1

General requirements

3.1.1

Overview of the measuring cycles

Function of the measuring cycles
The following table describes all the measuring cycle functions for the turning and milling
technologies.
Table 3-1
Measuring cycles
Measuring cy‐
Description
cle
CYCLE973
This measuring cycle can be used to calibrate a workpiece
2)
probe on a surface on the workpiece or in a groove.
CYCLE974
This measuring cycle can be used to determine the work‐
2)
piece zero in the selected measuring axis or a tool offset
with 1-point measurement.
CYCLE994
This measuring cycle can be used to determine the work‐
2)
piece zero in the selected measuring axis with 2-point
measurement. To do this, two opposite measuring points
on the diameter are approached automatically in succession
CYCLE976
Using this measuring cycle, a workpiece probe can be cali‐
brated in a calibration ring or on a calibration ball completely
in the working plane or at an edge for a particular axis and
direction.
CYCLE961
This measuring cycle can be used to determine the position
of a workpiece corner (inner or outer) and use this as work
offset.
CYCLE977
This measuring cycle can be used to determine the center
point in the plane as well as the width or the diameter.
CYCLE978
This measuring cycle can be used to measure the position
of an edge in the workpiece coordinate system.
Measuring cycles
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
Measuring versions
● Calibrate probe - length
● Calibrate probe - radius on surface
● Calibrate probe - probe in groove
● Turning measurement - front edge
● Turning measurement - inside diameter
● Turning measurement - outside diameter
● Turning measurement - inside diameter
● Turning measurement - outside diameter
● Calibrate probe - length on surface
● Calibrate probe - radius in ring
● Calibrate probe - radius on edge
● Calibrate probe - calibration on sphere
● Corner - right-angled corner
● Corner - any corner
● Edge distance - groove
● Edge distance - rib
● Hole - rectangular pocket
● Hole - 1 hole
● Spigot - rectangular spigot
● Spigot - 1 circular spigot
● Edge distance - set edge