2.14 Reference point approach (R1)
2.14.2

Signals from channel (DB21, ...)

DB21, ...
DBX36.2
All axes that have to be referenced are referenced
Edge evaluation: no
Signal state 1 or
All axes that must be referenced (linear axes and rotary axes) of the channel are referenced.
edge change
The machine data:
0 → 1
MD20700 $MC_REFP_NC_START_LOCK (NC start inhibit without reference point)
is zero.
If two position measuring systems are connected to an axis, that would prevent an NC start, then
the active one must be referenced so that the axis is considered to have been referenced.
An NC Start command for parts program processing is only accepted when this signal is present.
Axes that have to be referenced are axes, if:
MD34110 $MA_REFP_CYCLE_NR _ = -1
and the axis is not in the parked position (position measuring system inactive and the controller
enable withdrawn).
Signal state 0 or
One or more axes of the channel have not been referenced.
edge change
1 → 0
Special cases,
The spindles of the channel have no effect on this interface signal.
errors, ......
Corresponding to ....
DB31, ... DBX60.4 (referenced / synchronized 1)
DB31, ... DBX60.5 (referenced / synchronized 2)
2.14.3

Signals to axis/spindle (DB31, ...)

DB31, ...
DBX2.4 - DBX2.7
Reference point value 1 to 4
Edge evaluation: no
Signal state 1 or
When the reference cam is reached, the NCK is signaled which coded reference cam is actuated.
edge change
The interface signal:
0 → 1
DB31, ... DBX2.4 - DBX2.7 (reference point values 1 to 4)
must remain set until the reference point is reached,
or until a new coded reference cam is actuated.
If the machine axis has reached the reference point (axis stationary) then using the reference point
value pre-selected using
IS "reference point values 1 to 4" from the machine data:
MD34100 $MA_REFP_SET_POS (reference point value)
is transferred into the control as the new reference position.
Signal state 0 or
No effect.
edge change
1 → 0
Signal irrelevant for
Linear measurement systems with distancecoded reference marks
...
112
Signal(s) updated: cyclic
Signal(s) updated: cyclic