Module Supervision; Module Faults Send Reports; Module Faults Set Trouble Output; Rps Settings - Bosch Conettix B465 Installation And Operation Manual

Universal dual path communicator
Hide thumbs Also See for Conettix B465:
Table of Contents

Advertisement

76
en | System Configuration
When the B465 removes voltage from the PNL LINE 2 terminals (terminals for panel phone line
2), the control panel connected to the terminals creates a phone line failure event or a
communication failure event.
USB Menu Location
[4] System Configuration > [5] Communication Failure Action > [4] Comm Fail removes line 2
phone voltage
8.6

Module Supervision

Use the parameters in this section to configure the B465 to send reports and set the Trouble
LED and output when there is an internal fault (trouble).
8.6.1

Module Faults send reports

Default: Enabled
Selections:
The B465 sends reports in the Contact ID (SIA DC-05) reporting format.
USB Menu Location
[4] System Configuration > [6] Module Supervision > [1] Module Faults send reports
8.6.2

Module Faults set Trouble Output

Default: Disabled
Selections:
USB Menu Location
[4] System Configuration > [6] Module Supervision > [2] Module Faults set Trouble Output
8.7

RPS Settings

8.7.1

RPS Passcode

Default: 999999
Selections: 6 to 24 alphanumeric characters
RPS sends the RPS passcode to the control panel to establish a connection.
Enter a minimum of six characters. Do not use spaces in the passcode. The passcode is case-
sensitive.
USB Menu Location
[4] System Configuration > [7] RPS Settings > [1] RPS Passcode
8.7.2

Answer RPS over Network

Default: Enabled
Selections:
USB Menu Location
[4] System Configuration > [7] RPS Settings > [2] Answer RPS over Network
8.8

USB Terminal Passcode

Default: B465
Selections: 4-23 ASCII characters (no spaces)
2017.11 | 05 | F.01U.311.207
Enabled - the B465 sends trouble reports for module faults.
Disabled - the B465 does not send trouble reports for module faults.
Enabled - when there is a module fault event, the B465 sets the system trouble output.
Disabled - the B465 does not set the system trouble output for module fault events.
Enabled - enables automatic RPS initiated connections through the onboard Ethernet
communicator or plug-in cellular communicator.
Disabled - prevents automatic RPS initiated connections over the network.
Installation and Operation Manual
Conettix Universal Dual Path Communicator
Bosch Security Systems, Inc.