Locations and Functions of Parts
BKFV-100 boards (optional)
HD OUT
LINK A
1
2
1 LINK A 1, 2, 3
connectors
3
LINK B
1
2
2 LINK B 1, 2, 3
connectors
3
MONITOR
(SUPER)
1
2
3 MONITOR (SUPER)
1, 2, 3 connectors
3
TC
4 TC connector
SQ
5 SQ connector
HD OUT board
1 LINK A 1, 2, 3 connectors (BNC-type)
Supply the HD LINK A signals selected from the menu.
2 LINK B 1, 2, 3 connectors (BNC-type)
Supply the HD LINK B signals selected from the menu.
3 MONITOR (SUPER) 1, 2, 3 connectors
(BNC-type)
Supply analog video signals for monitoring with a
character signal superimposed. Connect to the input
connectors of the video monitors.
4 TC connector (BNC-type)
Supplies a timecode signal.
5 SQ connector (BNC-type)
Supplies a sequential signal.
6 LINK A connector (BNC-type)
Accepts the HD A signal selected from the menu.
12
HD IN
LINK A
6 LINK A connector
MONI-OUT
7 MONI-OUT
connector
LINK B
8 LINK B connector
MONI-OUT
9 MONI-OUT
connector
HD IN board
7 MONI-OUT (monitor output) connector
(BNC-type)
Supplies the signal input to the LINK A connector for
monitoring.
8 LINK B connector (BNC-type)
Accepts the HD B signal selected from the menu.
9 MONI-OUT (monitor output) connector
(BNC-type)
Supplies the signal input to the LINK B connector for
monitoring.