9.3.6
Technical data
Table 9- 70
Safety
Degree of protection
Protection class
Approvals
Electrical data
Rated voltage
Rated current
Power consumption at rated load
Power loss
Mechanical data
Dimensions WxHxD
Weight, approx.
For detailed technical data relating to the inputs and outputs, see the "Connecting" chapter.
X111, X222 and X333 digital inputs/outputs (Page 125)
Analog X3 inputs/outputs (Page 131)
9.4
COM01.3 RS 232C (V.24) module
9.4.1
Description
The COM01.3 RS 232C (V. 24) option board can be inserted into the option slot of the
Control Unit.
The control units can be connected to a master computer or modem via COM port X491.
The COM port has been designed in accordance with the "ANSI/EIA/TIA-232-F-1997"
standard.
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
Technical data of the I/O module
IP 00 according to EN 60529
III; DVC A, (PELV) acc. to EN 61800-5-1
cULus, CE
24 V DC
0.7 A
19 W (without digital outputs)
18 W
150 x 300 x 35 mm
0.9 kg
Connectable components
9.4 COM01.3 RS 232C (V.24) module
147