1 Introduction
1.9.2 Logging via CP315 with the SINUMERIK 840/880
•
Part 2
In Part 2, the fixed texts and variables of the log header are described as well as the
locations of date, time of day and page number.
The maximum header size is 2000 characters:
(characters per line+6) · number of lines of header 2000.
Part 2 consists of:
–
Definition of fixed texts
Code:
(@F * ZZ * SS @ABCDEFG12345@ @XYZ987@ )LF
Column No.
Line No.
Identifier for fixed text
–
Definition of variables
Code:
(@V * ZZ * SS @Rxxx * Fyy.z )LF
The last fixed text line must not be followed by a line with a variable without fixed text.
Remedy: Write additional fixed text, e.g. (@F
variable.
The R parameters for header data must be programmed as a continuous area and in
ascending sequence.
–
Definition of page numbers
Code:
(@S * ZZ * SS )LF
The page number has two decimal places. The column specifications refer to the 10th
place.
1–30
Column No.
(reverse to the leading place
of the decimal number)
Line No.
Identifier for variable
Column No.
Line No.
Identifier for page number
©
Siemens AG 1990 All Rights Reserved
Fixed text
(Number is variable)
(A maximum of 16 characters can
be entered at the same time).
Output format
yy=Maximum number of decimal
places (without sign, including the
decimal point)
z=Number of decimal places after
decimal point
No. of R parameters
e.g. R 49
Max. 3 digits,
leading zeros
can be ignored
ZZ
SS @ @)LF in the line containing the
*
*
SINUMERIK 840/850/880 (BN)
10.91
6FC5197- AB70