Calculation of the 24 VDC Power Requirement Example
Table 5-21
Component
NCU7x0
8 digital outputs
Active Line Module 36 kW
Motor Module 18 A
Motor Module 30 A
SMC
Brake
Total:
The following conditions should be considered for the configuring:
● The line infeed of the power supply devices must be tapped in front of the line filter of the
● The line connection of the power supply should be made directly and without additional
● The dimensioning of the output rated current of the power supply is determined by the
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
Example of 24 V DC current requirements
Line Module.
switched feeders.
load of the connected consumers.
Number
Current consumption
[A]
1
2,00
8
0,01
1
1,50
2
0,85
3
0,90
5
0,25
5
1,10
Connection of the Components
5.6 Electronics Power Supply
Typical current consumption [A
1,15
1,15
1,15
1,3
0,25
0,25
0,33
0,19
0,19
0,24
0,24
0,5
Total current consumption [A]
]
DC
2,00
0,08
1,50
1,70
2,70
1,25
5,50
14,73
5-45