Locations and Functions of Parts and Controls
Rear panel
12
3
4
5
6
1 ID selector
When two or more ICU controllers are used in the
system, set the ID number for each ICU controller.
For details, see page 15.
2 MODE selector
This is provided for future extended use. Normally set
to 0.
3 EXTERNAL CONTROL connector (D-sub 15-
pin)
Connect to the power distribution panel of the system.
4 CONTROL 1 connector (D-sub 15-pin)
Connect to the CONTROL1, CONTROL 2,
CONTROL 3 or CONTROL 4 connector of the ICU.
5 COM1 and COM 2 connectors (D-sub 9-pin)
Connect to the computer or the modem.
6 AC IN connector
Connect to an AC power supply of 100 – 240 V AC.
Use the supplied AC power cord which fits the AC
outlet in your area.