Siemens SINAMICS S120 Equipment Manual page 203

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 6- 24
Table 6- 25
Table 6- 26
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
Max. pulse frequency when a dv/dt filter compact plus Voltage Peak Limiter is used in
Power Modules with a rated pulse frequency of 2 kHz
Order number
6SL3315-1TE32-1AAx
6SL3315-1TE32-6AAx
6SL3315-1TE33-1AAx
6SL3315-1TE35-0AAx
Max. pulse frequency when a dv/dt filter compact plus Voltage Peak Limiter is used in
Motor Modules with a rated pulse frequency of 2 kHz
Order number
6SL3325-1TE32-1AAx
6SL3325-1TE32-6AAx
6SL3325-1TE33-1AAx
6SL3325-1TE35-0AAx
Max. pulse frequency when a dv/dt filter compact plus Voltage Peak Limiter is used in
Motor Modules with a rated pulse frequency of 1.25 kHz
Order number
6SL3325-1TE36-1AAx
6SL3325-1TE38-4AAx
6SL3325-1TE41-0AAx
6SL3325-1TE41-4AAx
6SL3325-1TG31-0AAx
6SL3325-1TG31-5AAx
6SL3325-1TG32-2AAx
6SL3325-1TG33-3AAx
6SL3325-1TG35-8AAx
6SL3325-1TG38-1AAx
6SL3325-1TG41-0AAx
6SL3325-1TG41-3AAx
6.4 dv/dt filter compact plus Voltage Peak Limiter
Unit rating
Output current for a
[kW]
pulse frequency of 2 kHz
[A]
Supply voltage 380 – 480 V 3 AC
110
210
132
260
160
310
250
490
Unit rating
Output current for a
[kW]
pulse frequency of 2 kHz
[A]
Supply voltage 510 – 750 V DC
110
210
132
260
160
310
250
490
Unit rating
Output current for a
[kW]
pulse frequency of 1.25
kHz [A]
Supply voltage 510 – 750 V DC
315
605
450
840
560
985
800
1405
Supply voltage 675 – 1080 V DC
90
100
132
150
200
215
315
330
560
575
800
810
1000
1025
1200
1270
Motor-side power components
Max. pulse frequency when a
dv/dt filter compact plus
Voltage Peak Limiter is used
4 kHz
4 kHz
4 kHz
4 kHz
Max. pulse frequency when a
dv/dt filter compact plus
Voltage Peak Limiter is used
4 kHz
4 kHz
4 kHz
4 kHz
Max. pulse frequency when a
dv/dt filter compact plus
Voltage Peak Limiter is used
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
201