Siemens SINAMICS S120 Equipment Manual page 103

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Order number
Max. cable length
(total of all motor cables and DC link)
- shielded
- unshielded
Degree of protection
Dimensions
- Width
- Height
- Depth
Frame size
Weight
UL listed fuse
4)
- Number (connected in parallel)
- Rated current
- Frame size acc. to IEC 60269
Valid for a 5 s duty cycle (overload duration) and a duty cycle duration of 300 s based on the base load DC link current
1)
I
.
H_DC
The specified power loss is the maximum value at 100% capacity utilization. In normal operation a lower value is
2)
established.
This value applies to the water coolant option; for other coolant types, see Chapter "Cooling circuit and coolant
3)
properties".
To achieve a UL-approved system, it is absolutely essential to use the fuse types specified in the table.
4)
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
6SL3335–
1TE37–4AA3
m
2600
m
3900
IP00
mm
160
mm
1137
mm
545
FBL
kg
108
3NE1333-2
2
A
450
2
4.2 Basic Line Modules
1TE41–2AA3
1TE41–7AA3
4000
4800
6000
7200
IP00
IP00
160
160
1137
1562
545
545
FBL
GBL
108
185
3NE1435-2
3NE1438-2
2
2
560
800
3
3
Line Modules
101

Advertisement

Table of Contents