4 Mode of operation
4.2.4

Periodic screen change of the initial screen

The start screen of the message text block [B055] is activated by the input
(enabled) and, through the marker [M25], switches the white background
illumination of the LOGO! display on.
The subsequent pulse generator [B057] is activated, whereby the pulse/pause ratio
is 2s each. This switches on the second message text of the source screen for 2s
every 2s.
If several message texts are active at the same time, the message text with the
higher priority is displayed at position (1), as
As a result, the display of the message texts (2) changes and a flashing text
appears: "Next: (F4)".
Alternatively, you can use this method to display changing message texts with
complementary information.
Figure 4-6: Periodic screen change of the initial screen
LOGO! 8 TDE Central control for individual switching of general consumers
Entry ID: 109755864,
V1.0,
04/2018
Figure 4-6
shows.
1
2s
2
16