Replacing an HDD/SSD

This section describes the procedure for replacing an HDD/SSD.
Location of installing HDD/SSD
Install an HDD/SSD to extension storage bays. The locations of the extension
storage bays are as follows.
Extension storage
Bay1 Bay3
Bay2
Figure 4-1: Location of extension storage bay
The correspondence between the extension storage bay numbers and the bay
configuration label on the side tab of the system are as follows.
Table 4-1: Extension storage bay and Bay configuration label
Extension storage bay
1
2
3
4
Removing an HDD/SSD
1. Confirm the failed HDD/SSD.
The HDD status LED on the HDD tray lights solid amber.
2. Push the tab of HDD tray to unlock the HDD/SSD.
3. Pull the lever open, and then pull out the failed HDD/SSD slightly.
4-2
Bay5 Bay7
Bay4 Bay6 Bay8
5
6
7
8
When replacing a failed HDD/SSD in hot-swap condition, you need the
following conditions.
Configure a disk array with redundancy (RAID1,5,6, or 10)
Disk array is operating in degraded mode.
Or disk array is performing or finishing rebuilding data to a reserve
disk with hot spare function.
Replacing parts