4 Repair
4.21 Replacement of sensors for the drive system fans
Continued
Removal
1
2
3
4
5
6
7
Continues on next page
272
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
Make sure that the main
power has been switched off on page
Remove the moist dust filter magazine.
(Option)
Loosen the four attachment screws to the
cover.
Remove the cover.
Disconnect the connectors to the fan.
Slide the cable gland out of the indentation.
Push the fan upwards and remove it.
© Copyright 2004-2018 ABB. All rights reserved.
Note /illustration
26.
How to remove the moist dust filter
magazine is detailed in section
ment of moist dust filter on page
xx1500000855
A Connectors
A
B
C
xx1500000856
A Fan
B Latches
C Grooves
D Temp sensor cable
E Cable gland
Product manual - IRC5
3HAC047136-001 Revision: M
Replace-
187.
A
E
D

Hide quick links: