Basic Positioner - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.9

Basic positioner

General description
The basic positioner is used to position linear and rotary axes (modulo) in absolute/relative
terms with motor encoder (indirect measuring system) or machine encoder (direct measuring
system). It is available in the servo and vector modes.
User-friendly configuration, commissioning, and diagnostic functions are also available in
STARTER for the basic positioner functionality (graphic navigation). In STARTER, there is a
control panel for the basic positioner and speed-controlled operation; using this control
panel, the functionality can be started from a PC/PG to commission the system or carry out
diagnostics.
When the basic positioner is activated (r0108.4 = 1), then the position control (r0108.3 = 1)
should also be activated. This is realized automatically when activating the basic positioner
via the STARTER commissioning wizard. Further, the necessary "internal interconnections"
(BICO technology) are automatically established.
The basic positioner requires the position controller functions. The BICO interconnections
established by the basic positioner must be changed by experienced users only.
This means that naturally the position control functions are also available (e.g. standstill
monitoring, positioning monitoring, dynamic following error monitoring, cam controllers,
modulo function, measuring probe evaluation). Also refer to the section "Position control".
In addition, the following functions can be carried out using the basic positioner:
● Mechanical system
● Limits
● Referencing or adjusting
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
CAUTION
– Backlash compensation
– Modulo offset
– Position tracking of the load gear (motor encoder) with absolute encoders
– Traversing profile limits
– Traversing range limits
– Jerk limitation
– Set reference point (for an axis at standstill that has reached its target position)
– Reference point approach
(autonomous mode including reversing cam functionality, automatic direction of
rotation reversal, referencing to "cams and encoder zero mark" or only "encoder zero
mark" or "external equivalent zero mark (BERO)")
– Flying referencing
(during the "normal" traversing motion, it is possible to reference, superimposed, using
the measuring probe evaluation; generally, evaluating e.g. a BERO. Higher-level
(superimposed) function for the modes "jog", direct setpoint input/MDI and "traversing
blocks")