Samsung OfficeServ 500 Service Manual page 96

Hide thumbs Also See for OfficeServ 500:
Table of Contents

Advertisement

CHAPTER 5. Maintenance
Upgrading a New Software
The 8WLI card can upgrade the software by downloading WLIROM HEX file and
MWLIROM.HEX file via the console terminal. After storing both files in the console
terminal, download them following the method below.
1) When the 8WLI card is normally operated, the following message will show up.
Click the [ENTER] key.
VoWLAN Console <8-Port WLI Board>
2) Enter the 'flo' command at the prompt and click the [ENTER] key, the following
massage will show up.
<WLI>flo
================== Select One =======================
[1] Single WLI
[2] Multi
[R] Restart
3) Select '1' and load the WLIROM.HEX file, from the PC to the 8WLI card. Then
the following message will show up.
Selected 1> Single- WLI HEX FILE Loading
Please Start Loading!!
4) Click the 'Send file' on the File Menu of the Tera terminal window.
5) Then the <Sending the text file> window will show up. Select the WLIROM
HEX file and click the [Ok] button.
6) While the WLIROM HEX file is being transmitted to the 8WLI card, the
transmitted contents will be indicated on the screen. If the file transmission is
completed, information on the transmitted HEX file will show up. It takes about
fifteen minutes to send the file to the 8WLI card.
Page 5-20
HEX FILE Loading <Addr = 0x00110000>
WLI
HEX FILE Loading <Addr = 0x00190000>
Prevention of executing the 'flo' command
If the 'flo' command is executed, the power of all base stations connected to the 8WLI
card is turned off and their wireless LAN function will be interrupted.
OfficeServ 500 Wireless LAN Service Manual/Ed.00
© SAMSUNG Electronics Co., Ltd.