10 | Analog and Frequency Inputs
10.3.3
72 / 160
Channel is linked
to ANA04
Input pin Pull-up
resistor is
activated
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
Configuring a generic nonlinear sensor
Example: Thermistor 5 kOhm
▪ From sensor data sheet: resistance values over temperature
▪ The sensor has a nonlinear behaviour
▪ Use characteristic curve for linearization
▪ Input voltage is the ratio between pull‐up resistor and thermistor
+5V
Pin
3 kOhm
Thermistor
1. Click 'Measurement Sources' in the Toolbox.
2. Expand the list of 'I/O Channels' by clicking on '+' in the DDU 7 Project Tree.
3. Drag the 'Characteristic Curve' analogue signal source from the Toolbox and
drop it on the desired analogue input channel in the DDU 7 Project Tree.