Philips SOPHO SuperVisor 25 Engineer's Manual page 44

Table of Contents

Advertisement

LOCKEY D.;856749;DEVELOPMENT;765489
SMITH K.;856749;DEVELOPMENT
The Status Monitoring File
The Status monitoring file format is as follows:
<entry number>;<DNR/line number><CR>
-
Entry number
The entry number is a number in the range 1 ... 60. Each number represents a status line
on the display. Entry numbers 1 ... 60 covers 6 pages of 10 entries each.
Note: In SuperVisor model 25 with S
case the analogue interface of model 25 is used, status monitoring is not possible.)
-
DNR/line number
The DNR/line number represents a DNR range of 10 DNRs or the line number. A
maximum of 5 digits may be entered.
If a DNR range is specified, the DNR must be entered without the least significant digit.
If a line number is entered, it must be preceded by a . or a # to indicate that the digits
represent a route/line number instead of a DNR range. The line number that follows the
'dot' or the 'hash' must be three digits.
Example: if you want to monitor the lines 72 up to 78 you enter: dot 007 (leading zero's
must be added).
If a line number is already present in the file, it will be ignored when the file is stored into
the console.
The following gives an example of a status monitoring file:
1;123
2;124
29;#007
30;#021
Speed Dialling Key File Format
The Speed Dialling Key file format is as follows:
<entry number>; <name>;<DNR><CR>
42
bus only 1 page is available covering entries 1 ... 10. (In