6.1.1
PWA-DWNLD-350-JIG2 (48 MB)
The master data written on the hard disk can be updated by using PWA-DWNLD-350-JIG2 (48 MB).
Update the master data according to the need such as the case of replacing the hard disk.
The data to be overwritten are as follows.
•
HDD program data (RIP data, list data, Web data, filing box control data)
•
UI data (fixed section data, common section data, the language 1 to 7 data, the language 1 to 6 data
for Web)
[A] Update procedure
Important:
•
Use the download jig "PWA-DWNLD-350-JIG2 (48 MB)".
•
Turn OFF the power before installing and removing the download jig.
•
Do not turn OFF the power during the update. The data could be damaged and not be oper-
ated properly.
(1)
Write the data to the download jig.
P.6-21 "6.1.3 Writing the data to the download jig (PWA-DWNLD-350-JIG)"
(2)
Turn OFF the power of the equipment.
(3)
Remove the cover plate.
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Cover plate
Fig. 6-4
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
6 - 5
FIRMWARE UPDATING