Canopy T1/E1 Multiplexer
3.2 T1/E1 ALARMS
Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal
(LOS), and alarm indication signal (AIS) detection.
Follow these steps to display the alarms using the CLI.
Action
Log in
View T1/E1 Alarms
Log off
Issue 3
Procedure 23: Displaying the alarms using the CLI
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
Enter get alarms.
The system responds displays alarms for all 4 T1/E1 ports, as in the
following example:
Line1:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line2:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal
Line3:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line4:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
FPGA: 00
Enter lo.
RESULT: The system responds goodbye.
end of procedure
Page 54 of 73
T1/E1 Multiplexer FPGA Version 3.4
Steps
Detect: No
September 2004