NEC SigmaBlade N8406-040(F) User Manual page 137

8g fc switch
Table of Contents

Advertisement

Removal Procedure
Pull down the lever on the SFP+ module.
1.
N8406-040/042 4/8G FC Switch
Hold the lever and pull out the module in the arrow direction shown in the figure.
2.
IMPORTANT:
Before the SFP+ module can be removed, the lever should always be lowered. If the
SFP+ module is pulled out without the lever lowered, the SFP+ module and/or slot may
be damaged.
Put the dust covers attached to the SFP+ modules on them to protect the FC
connectors from dust.
Install a cap in SFP+ port from which the SFP+ module was just removed.
3.
IMPORTANT:
Put the cap attached to the 8G FC Switch on them to protect the SFP+ port from
dust.
There is't the caps for ports 17 and 18 at N8406-040.
There is't the caps for ports 17, 18, 19 and 20 at N8406-042.
SFP+ module
Pull down
the lever
Pull-out
direction
- 137 -