IF-1196 board
S301
D301
D302
D303
A
LED
D301 (A-1): DONE
Lit when the internal Init. of the touch panel IC is com-
pleted normally.
D302 (A-1): ACT
Lit when the signal is input to the touch panel.
D303 (A-1): NAK
Lit when the response to the command is NAK.
D401 (E-3)
Power status indication.
Lit when +5V is supplied normally.
D402 (C-3)
Power status indication.
Lit when +1.2V is supplied normally.
D403 (C-4)
Power status indication.
Lit when +3.3V_PLD is supplied normally.
D405 (E-2)
Power status indication.
Lit when +3.3V is supplied normally.
ICP-6520/6530/3000/6511
S600
S601 S602
B
C
Switch
S301 (A-1)
Used for the production in the factory. Do not change the
setting.
S600 (C-4): RESET
Initializes the IF-1196 board.
S601 (C-4): USER_STATUS
Used for the production in the factory. Do not change the
setting.
S602 (C-4): FPGA_MODE
Used for the production in the factory. Do not change the
setting.
D405
D401
D402
D403
D
E
IF-1196 board (Side A)
1
2
3
4
1-31 (E)