Attaching the Mounting Plate to the Wall
Step 2.1
2.1
Using a stud sensor, locate and mark the stud positions in the
wall where the indoor unit is to be mounted.
Step 2.2
2.2
Place the mounting plate on the wall in the desired location
taking into account the minimum clearances necessary for
proper operation.
Using a level, verify the mounting plate is horizontal and mark
the screw locations.
Step 2.3
2.3
Screw the mounting plate to the wall.
The piping for the indoor unit may be routed to the unit from
one of several directions. Left, Left Rear, Right, Right Rear, or
Below (Illustration 1).
Step 2.4
2.4
Knockouts are provided on the case for Left, Right, and Right
Below.
Drilling the hole through the wall for left rear or right rear
installation
Step 2.5A & 2.5B
2.5
Measure and mark the location where the piping hole is to be
drilled.
Step 2.1