Yamaha DM1000 Service Manual page 131

Digital production console/ peak meter bridge/wooden side panels
Hide thumbs Also See for DM1000:
Table of Contents

Advertisement

1)
CPU
Interface (Data Bus)
0000 0000 XXXX 0000 0000 0000 0000 X00X
MSB
X=
Connection (DSP7 → DSP6)
2)
SIO
1 IC201 S0[xx] → IC301 SI[xx]
NG:
--- MIDI Loopback ---
OK
MIDI Check
OK: SCI2
EXIT ([DEC] Key->[ENTER] Key)
--- 2TR IN/OUT ---
OK
FS
OK OUT-->IN
OK DIR Lock (RERR)
OK DIT,DIR CDIN,CDOUT
NG: DIO_SIO 2TR1 [W:12485100 -> R:00000000]
EXIT ([DEC] Key->[ENTER] Key)
... NG: IC201
LSB
...
DM1000/MB1000/SP1000
--- WORD CLOCK ---
OK
OUT->IN
NG PLL (DIR2,DBL)
NG PLL UnLock
Disconnect BNC cable
NG:DBL_PLL_48K_COUNT=220
EXIT ([DEC] Key->[ENTER] Key)
--- LCD ---
OK
Turn on LCD(white<-->black)
[ENTER] key to Start, [DEC] key to Stop
OK
NG
EXIT ([DEC] Key->[ENTER] Key)
131