Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Wink Signal Width
Specifies the length of a wink signal.
Value Range
32 ´ n (n=4–9) ms
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
DTMF Tone—DTMF Inter-digit Pause
Specifies the length of the DTMF inter-digit pause. This allows the telephone company to have enough time
to accept the dialled digits correctly.
Value Range
64 + 16 ´ n (n=0–11) ms
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
PC Programming Manual
219