Mounting standard metal fixtures
(Precautions for installing the optional speaker)
4.11.4 Precautions for mounting different metal fixtures after the optional speakers are attached to
the plasma display main body
When different metal fixtures are mounted after the optional speakers are mounted to the plasma display, the following
steps and precautions must be observed, depending on the specific type.
1) Tilted stand (PDK-4001)
Washer
(an accessory for the PDK-4001)
Bolt
(an accessory
for the PDK-4001)
Washer of φ 25-mm outer diameter
(an accessory for the optional speaker)
When mounting the optional speaker, tighten the PDK-4001 and optional speaker with the mounting screws
supplied with the PDK-4001. For the top, where no metal fixture for speaker is provided, adjust levels to make
flush, using the φ 25-mm outer diameter washers supplied with the speaker.
100
<Ver. 2.1>
Washer
Bolt
(an accessory
(an accessory
for the PDK-4001)
for the PDK-4001)
Fig. 1