Classifi-
Code
cation
1388
Counter
Number of output pages
(OHP film)
1410
Counter
Counter for period of toner
cartridge rotation time
1411
Counter
Counter for envelope
1628-0
Process-
Drum life correction switch-
ing
ing of the drum reverse
rotation amount
1628-1
Process-
Drum life correction switch-
ing
ing of the normal drum
rotation amount after the
reverse rotation
1913
Process-
The function clear LED
ing
blinks
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
PPC
2 - 56
06/05
Default
<Accept-
RAM
able
value>
0
M
Counts up when the
<8 digits>
registration sensor is
ON.
0
M
Counts up the period of
<8 digits>
rotation time of the
toner cartridge.
0
M
Counts up when the
<8 digits>
registration sensor is
ON.
4
M
Drum life correction
<0-15>
switching of the drum
reverse rotation amount
9
M
Drum life correction
<0-15>
switching of the normal
drum rotation amount
after the reverse rota-
tion
1
SYS
Blinks when the value is
<0-1>
different from the
present default value
after copying (until auto
clear or all clear.)
0: Invalid (Always off)
1: Valid