Download Print this page

Toshiba e-STUDIO163 Service Handbook page 70

Hide thumbs Also See for e-STUDIO163:

Advertisement

Classifi-
Code
cation
655
General
Reset the 05/08 codes
672
General
Initialization of Access
code
695
General
Toner remaining check
function (supports embed-
ded IC chip)
698
Paper
Limit function for the num-
feeding
ber of paper exit
699
Paper
Limit number setting for
feeding
paper exit
800-0
Fuser
Temperature
control lower
limit
(OHP film)
800-1
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
-
-
ALL
ALL
ALL
Center
ALL
thermistor
Side ther-
ALL
mistor
2 - 50
07/11
Default
<Accept-
RAM
able
value>
-
-
Returns the set value
for the 05/08 code to its
default value.
However, various
counter values of the 08
codes are not reset.
-
SYS
Initializing of the Access
code
*
Key in the code and
press the [START]
button to perform
the initialization.
EUR: 1
M
Checks whether the
UC: 1
toner cartridge is
CND: 0
inserted or not.
Other: 1
0: Check function dis-
<0-1>
abled (08-971 is
automatically
changed to "3:
Toner near-empty
detection disabled".)
1: Check function
enabled (08-971 is
automatically
changed to "1:
Toner near empty
threshold value
(standard)".)
1
M
Sets if the MFP controls
<0-1>
the paper exit full status
or not. If "0" is set to 08-
698, the MFP will not go
into the paper exit full
status.
0: OFF
1: ON
Number set at 08-699
will be set as the limit
number of paper exit.
250
M
When the counter
<1-999>
reaches the value spec-
ified, the MFP goes into
the paper exit full sta-
tus. Sets the limit num-
ber of paper exit for 08-
698.
7
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
5
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
-
3
1
1
1
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4

Hide quick links:

Advertisement

loading