Operational Check

The operational check tests the communication link between the remote control and the
DCT1800. The procedures verify the DCT1800 response to remote control commands.
Table 3-1 lists the operational check procedures:
Table 3-1
Operational check
Feature
Power on
Channel Selection
If the DCT1800 does not operate properly, refer to Section 4, " Troubleshooting" .

Cold Initialization

The DCT1800 has no front panel buttons. To perform a cold initialization, or reset, use the
remote control.
To execute a cold initialization:
1
Hold down any key on the remote control while disconnecting and reconnecting AC power to
the DCT1800.
After booting up, the
2
Within 3 seconds, press the 3 key on the remote control.
The
LED on the DCT1800 front panel flashes at a decreased rate.
POWER
3
Within 3 seconds, press the 2 key on the remote control.
The
LED on the DCT1800 front panel flashes at an increased rate.
POWER
4
Within 3 seconds, press the 8 key on the remote control to initiate the cold reset.
During the cold initialization procedure, if the appropriate remote control key is not pressed
within the three-second time period, the procedure terminates and the DCT1800 resumes
normal operation.
Testing Procedure
!
Press
to turn on the DCT1800.
POWER
!
Turn on the TV and tune it to the output channel of the DCT1800 (channel 3
or 4).
Tune to several channels by entering the channel number with the numeric keys on
the remote control.
LED on the DCT1800 front panel will flash.
POWER