SYNTAX DF
terminator
EXPLANATIONNo parameters
are used; a numeric parameter
will
cause error 2 and the instruction will not execute.
A DF command sets the following plotter functions to the conditions
shown in the following table. P1 and P2 are not changed.
Default Conditions
Function
Conditions
Plotting mode
Absolute (PA)
Relative character direction
Horizontal (DR1,0)
Line type
Solid line
Line pattern length
4% of the distance from P1 to P2
Input window
Mechanical limits of plotter
Relative character size
Width = 0.75% of (P2X—Plx)
Height = 1.5% of (P2y —Ply)
Symbol mode
Off
Tick length
tp = tn = 0.5%of (P2X- Plx) for Y-tick
and 0.5% of (P2y —Ply) for X-tick
Standard character set
Set 0
Alternate character set
Set 0
Character set selected
Standard
Character slant
0 degrees
Mask value
223,0,0
Digitize clear
On
Scale
Off
Pen velocity
38.1 cm/s (15 in./s)
Label terminator
ETX (ASCII decimal equivalent 3)
Chord angle*
Set to 5 degrees for AA, AR, and CI
*Applicable only to Option O01 plotters that have the serial prefix number
2308Aor higher.
The Initialize Instruction, IN
UESCWP-"UN The initialize instruction, IN, returns the plotter's
graphics conditions to the initial power—on state by program control.
This instruction has no effect on handshake protocol or the plotter's
state (programmed on or programmed off) in an RS—232—C
environment.
The instruction can be used to return the plotter to a known
state at the beginning of a graphics program so unwanted graphics
parameters such as character size, slant, and scaling are not inherited
from another program. P1 and P2 are set to power—on p ositions.
SYNTAX IN
terminator
GETTING STARTED 1-11