Checking The Drainage And Pipe Forming - LG AMNH096BTG0 Manuals

Multi type air conditioner
Hide thumbs Also See for AMNH096BTG0:
Table of Contents

Advertisement

Installation

Checking the Drainage and Pipe forming

1. Split Type Indoor Unit
1) Remove the Grille from the cabinet
• Set the up-and-down air direction louver to
open position(horizontally) by finger pressure.
• Remove the securing screws.
• To remove the Grille, pull lower the left and
right side of the grille toward you (slightly tilted)
and lift it straight upward.
2) Check the drainage
• Pour a glass of water on the evaporator.
• Ensure if water flows drain hose of indoor unit
without any leakage.
2. Art Cool Type Indoor Unit
• Pour a glass of water on the evaporator.
• Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Pull the right and
the left side.
- 74 -