Example Dial Plan
238
Parameter
Digit string
011
Action
S
Minimum length 4
Maximum length 13
Timer
3
Terminating
#
Character
Summary: Any numbers that start with 011 and have a length of 13 digits are
sent to the server immediately. Shorter numbers with a length from 4 digits
onwards are sent after a 3 seconds delay.
11) The example dial plan is completed; it should look like this:
12) You can check the dial plan using the phone's web interface; navigate to
Diagnostics > Fault trace configuration > Download dial plan file.
Related Topics
OpenScape Desk Phone IP, Phone Administration, Administrator Documentation
Value
Description/Remarks
This rule matches numbers beginning with 011. In
the USA, this digit string is the prefix international
calls.
When the entered digit string reaches the Minimum
length, the Timer is started. On expiry, the digit
string is sent.
When the length of the digit sequence entered by
the user reaches this value, the Timer is started.
When the length of the digit sequence entered by
the user reaches this value, the digits are sent to the
server immediately. The Timer is overridden.
When the length of the digit sequence entered by
the user reaches the Minimum length, the phone
waits 3 seconds for further digits. If the user does
not enter any further digits, the Action is triggered.
When this character is entered, the digits are sent to
the server immediately, regardless of the criteria
contained in this rule.