Yamaha 01x Service Manual page 67

Digital mixing studio
Hide thumbs Also See for 01x:
Table of Contents

Advertisement

1.
Foreword
1.1
Contents
The description of each test item consists of following contents.
1. Outline
2. Operation method under normal state
3. Operation method under faulty state
4. Item description and error message
5. Check point when judged as NG
1.2
Expression of message
The LCD display of the main unit and other items are expressed
in the text as described below.
LCD
Enclosed in a rectangular frame.
Panel operation element Identified by square brackets ([ ]).
TEST NUMBER
Each test is numbered individually.
It is the same number as the one used
when selecting the test (given in the
LCD display at the upper left).
2.
mLAN Function Check
For the mLAN function check (Item 4.14) of this Test Program,
it is necessary to connect O1X (MLN2 P.C.B.) and the PC and
set the application software for testing in advance.
2.1
Items required for inspections
DOS/V PC with WindowsXP Professional installed
• With CPU of CPU clock 2.2GHz or more included
• 512MB or more system memory
• Single Processor (other than Multi Processor)
• COM (general purpose, serial) terminal provided
• IEEE1394 terminal in conformity to OHCI provided, or
equivalent terminal provided by an extended slot card
IEEE1394 (mLAN) cable: 1 pc.
Foot switch (FC4, FC5)
Coaxial cable (75Ω)
MIDI cable
Oscillator
Monitor speaker
Head phone
Immediately after installing the OS to the DOS/V PC, adjust
Windows XP using the following procedure.
1) Make sure that the virus detection software will not be
activated.
2) Make sure that Windows will not be updated
automatically.
3) On the control panel, select System -> Settings ->
Performance -> Performance option setting and set the
visual effect to "Priority on performance".
4) On the control panel, select System -> Settings ->
Performance -> Performance option setting and set the
processor schedule to "Background Service".
5) Make sure that the screen savor or the power saving
function of the monitor will not be activated to prevent
sleeping.
2.2
Installing mLAN driver and test program
To the DOS/V PC with WindowsXP Professional installed,
install the mLAN driver and test program in advance
according to the following procedure.
• Installing mLAN driver
1
Turn on the power to the DOS/V PC.
2
Download the following 3 foldersin
mLanTester_for_Service_v1 from YSISS Home Page.
1) mLanInstaller (0.6.5d4)
2) mLan Tester
3) Release Data
3
Execute "Setup.exe" in mLanInstaller (0.6.5d4).
4
When the installer is activated, operate the DOS/V PC
according to the instructions of the installer.
5
Connect the O1X to the DOS/V PC and turn on the power
to the O1X.
6
Make a setting for "mLAN Auto W.CLK=Enable" by
operating the O1X.
7
When the screen asking about "ASIO/WDM mode"
appears, select "ASIO".
(Do not select "WDM" or "WDM+ASIO".)
8
Once installation is completed, "AutoConnector for
01X" is automatically activated. Then make settings on
the dialog box as follows.
SampleRate: 48KHz
From 01X to PC: 24CH
From PC to 01X: 18CH
*
The version of the driver is 0.6.5d4.