Operating the Printer
2. Hardware Errors (Call maintenance personnel if it cannot be resolved)
LCD message
Abnormal high
temp print head
Cutter save err.
Cutter cut error.
CMOS sum check
Error
CMOS data
offset illegal
DOS LOAD xxx
(xxx: 3digs,decimal)
DOS LOAD 009
EEPROM write
count excessive
EEPROM data
offset illegal
Error
0x00-0x00-0x00
hh:mm mm/dd/yyyy
(hh:hour, mm:min.
mm:month, dd:date
yyyy:year)
POST MESSAGE
CODE=xx
Printing error
in thermal head
Print head
approach error
Print head ther-
mistor abnormal
Pulse motor err.
driver PM x
(x: 1,2,3,4,5,6)
Pulse motor err.
Slew. Timer x
(x: A,B,C,D,E,F)
SYS ERROR P0xxx
POWER RESET
(xxx: 3digs,decimal)
SYS ERROR P0700
POWER RESET
SYS ERROR P0800
<ENT>
SYS ERROR S0020
POWER RESET
LED
B.Z. C.f.
E-Code
ERROR
ON
H
A-2600
ERROR
ON
H
A-2000
ERROR
ON
H
A-2100
ERROR
ON
H
A-6000
ERROR
ON
H
A-73xx
-
-
H
-
-
-
H
-
ERROR
ON
H
A-6100
ERROR
ON
H
A-74xx
ERROR
ON
H
A-0000
-
ON
H
-
-
-
H
-
ERROR
ON
H
A-2200
ERROR
ON
H
A-2700
ERROR
ON
H
A-2400
A-2310
ERROR
ON
H
11-14,1A
A-2315
ERROR
ON
H
16-19,1B
ERROR
ON
H
-
ERROR
ON
H
-
ERROR
ON
H
-
ERROR
ON
H
-
7
Description
The temperature of print head exceeds the specified limit.
Try to POWER OFF/ON. If the same error results,
call maintenance personnel.
Cutter did not move to initial position.
Remove the jammed ticket and close the cover.
Ticket was not cut.
Remove the jammed ticket and close the cover.
Checksum error is detected in the CMOS.
Try to POWER OFF/ON.
maintenance personnel.
CMOS data is invalid.
Try to POWER OFF/ON.
maintenance personnel.
DOS system error occurred.
Try to POWER OFF/ON.
maintenance personnel.
Drive not ready: no diskette on the drive
Try to POWER OFF/ON. If the same error results, call
maintenance personnel to check diskette or system board.
EEPROM write count exceeded the specified limit(9,999).
Call maintenance personnel to replace the EEPROM.
EEPROM data is invalid.
Try to POWER OFF/ON.
maintenance personnel.
Error during BIOS setup.
CMOS configuration is bad.
If description (time and date) is not correct, input correct value
and push key "ENT" until auto-reboot the system.
Unexpected error in configuration.
Memorized the code number.
And call the maintenance personnel and tell the number.
The print data transferred to the thermal head does not complete.
Removes jam ticket and try to POWER OFF/ON.
If the same error results, call maintenance personnel.
Print head approach error
Removes jam ticket and try to POWER OFF/ON.
If the same error results, call maintenance personnel.
Abnormal temperature of print head thermistor is detected.
Removes jam ticket and try to POWER OFF/ON.
If the same error results, call maintenance personnel.
Over current of pulse motor PM1,2,3,4,5.
Removes jam ticket and try to POWER OFF/ON.
If the same error results, call maintenance personnel.
Over drive of pulse motor timing A, B, C, D, E, F
Removes jam ticket and try to POWER OFF/ON.
If the same error results, call maintenance personnel.
Errors during bootstrap phase:
Try to POWER OFF/ON. If the same error results, call
maintenance personnel to check system board.
Memorized the error number.
And call the maintenance personnel and tell the number.
Print head Failure:
Try to POWER OFF/ON. If the same error results, call
maintenance personnel to check print head.
Battery Alarm: Low voltage or disconnect with battery
Try to bootstrap with pushing key "ENT". If the same error
results, call maintenance personnel.
Fan Alarm during operation
Try to POWER OFF/ON. If the same error results, call
maintenance personnel.
Recovery
If the same error results, call
If the same error results, call