LG 52SX4D Service Manual page 15

Dlp projection tv
Hide thumbs Also See for 52SX4D:
Table of Contents

Advertisement

9-2. Adjustment Sequence
(1) When the program is executed, select MPLAB ICD2 from
"Programmer -> Select Programmer"
(2) Select "Configure -> Select Device".
(3) When the "Select Device" window appears, select
PIC18F242 from "Device" and press OK.
(4) Select "Programmer -> Connect".
ADJUSTMENT INSTRUCTIONS
When connected with the Micom, the display message on
the Output window appears as below.
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to MPLAB ICD 2
Target Device PIC18F242 found, revision = 0x7
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 Ready
(5) Select "File -> Import", select the Work HEX file and open.
(6) Select "Programmer -> Program".
(7) Download begins and about 3 seconds later, the
"Programming succeeded" message is displayed on the
Output window and the Download process is ended.
Note: Step (6) is more convenient when using the short-cut icon.
- 15 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

52sx4d-ub

Table of Contents