Kenwood CK 231 DF Instructions For Use Manual page 33

Gas cooker with electric double oven
Table of Contents

Advertisement

Gas connection (figs. 10.2, 10.3, 10.4)
The gas supply must use the nearest gas inlet pipe which is located at the left or the
right hand side at the rear of the appliance .
IMPORTANT: Check the correct positioning of the male connector as per
pictures and always operate using two suitable spanners.
The unused end inlet pipe must be closed with the plug and the fibre washer.
The hose should not be crushed or trapped or be in contact with sharp or abrasive
edges . It should also not be subjected to corrosion by acidic cleansing agents .

The hose should also be connected in such away that it does not touch the floor and
must hang in a natural loop between the appliance and the bayonet fitting.
To avoid damage to the appliance gas rail inlet pipe the fittings should be tightened
using two suitable spanners .
Fitting the 1/2" BSP
(male) connector
Gasket
The male
connector is
already
fitted on the left
or right inlet pipe
Left gas
inlet pipe
1/2" BSP (male)
Fig. 10.2
Right gas
inlet pipe
Plug
Fitting the plug on the
inlet pipe terminal not used
Cooker manifold
(Right or left
inlet pipe)
Manifold
male pipe fitting
1/2" G cylindrical
Gasket (#)
(ISO 228-1) male
Plug (#)
1/2" G cylindrical
(ISO 228-1) female
(#) Already fitted on the
right or left inlet pipe
Fig. 10.3
33