Adjustment Of Touch Panel (Function Code 61) - Brother DCP-9055CDN Service Manual

Color laser mfc
Hide thumbs Also See for DCP-9055CDN:
Table of Contents

Advertisement

1.4.18 Adjustment of touch panel (Function code 61)

<Function>
This function adjusts the detection area on the touch panel.
Note:
The adjustment procedure requires a stylus with a thin tip. A commercially available stylus
designed for electronic dictionaries or personal digital assistance (PDA) can be used. If
you do not have it on hand, order the "STYLUS" from the Brother's parts list.
<Operating procedure>
(1) Press the 6 and 1 buttons in this order in the initial state of the maintenance mode.
The adjustment screens shown below appear on the LCD.
(2) Touch the symbols on the touch panel with a stylus in the order of top-left, bottom-left,
bottom-right, top-right, and the center. After a symbol touched disappears, touch the next
one.
Note:
- Do not use tools other than a pen designed for touch panels. Especially, never use a
pointed one, e.g., a screwdriver. Using such a tool damages the touch panel.
- Do not touch the touch panel with fingers. The contact area of a finger is too large to
adjust the touch panel precisely.
- If no keys are pressed for one minute in the above procedure or you press the Stop/Exit
button, the machine stops the procedure and returns to the initial stage of the
maintenance mode.
When you press the symbol at the center (the 5th symbol), "OK" appears if the specified area
is correctly adjusted. Then, the screen shown below appears, and the machine returns to the
initial state of the maintenance mode in approximately 3 seconds.
Note:
If the way to press the symbol is wrong, or if a wrong place is pressed, "NG" appears on the
LCD, and the machine returns to the screen in step (2) in approximately 3 seconds. Be
sure to press the symbols from the top-left in the order shown above.
In the case of "NG", repeat this operation 2 to 3 times. If "NG" remains displayed even after
the operation is repeated, check if there is harness connection failure in the touch panel,
disconnection, short-circuit, or entry of foreign objects in the touch panel frame. Although any
of these problems is not observed, if "NG" is displayed, replace the LCD unit.
Fig. 5-21
5-38
Confidential

Hide quick links: