■ Error code E8
---
The scanned data fails to be recorded in the buffer RAM.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Step
1
Main PCB failure
■ Error code E9
Print Unable E9
Turn the power off and then back on again.
Main PCB error.
Step
1
Main PCB failure
■ Error code EA
---
Communication data error upon scanning.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Step
1
Main PCB failure
Cause
Cause
Cause
2-95
Remedy
Replace the main PCB ASSY.
Remedy
Replace the main PCB ASSY.
Remedy
Replace the main PCB ASSY.