14

Connecting the VC6000 Series Indoor

When using the VC6000 Series indoor, the VC6000 Series can be
placed on a desk and powered using an Indoor Power Supply Unit.
To connect the VC6000 Series indoor:
1.
Connect a ground wire between the VC6000 Series and the facility
ground system.
WARNING: To ensure proper grounding, use a 18AWG ground
The ground wire ring lugs should be connected to the Ground Point
(GND) at the back of the VC6000 Series using M4 screw.
AC Cord
12 V DC Cable
wire between the VC6000 Series Ground Point (GND)
and the facility ground system.
100-240 V AC / 50-60 Hz Power Outlet
Indoor Power Supply Unit
For indoor use only in dry locations
Power Connector
VC6000 Series Vehicle Computers
WWAN Antenna Connector
Ground Point
GND
WLAN Antenna
Connector