Options; 1/2 Load; Delayed Start; Cancelling A Programme - Electrolux “DIVA” EDW 500 Service Manual

Dishwasher with electronic control “diva” 45-60 cm
Table of Contents

Advertisement

5.1 Options

5.1.1

"1/2 load"

The 1/2 load option optimizes the washing cycle when only a small load is placed in the appliance.
When this button is pressed, certain parameters of the selected washing cycle are modified:
Exclusion of Pre-wash (if featured)
Reduction of the washing temperature
Reduction of the duration of the programme
5.1.2

Delayed start

This option enables the user to set a fixed start delay of the washing cycle.
to select the delayed-start time:
1. Select the desired programme by rotating the knob: LED LD0 lights up
2. Press the relative button to select the delayed-start time: the LED LD2 lights up to show that the
selection has been made.
The time reset when the relative button is pressed again: the LED LD2 switches off.
3. Pressing button S1 (Start), when the door is closed, the countdown starts.
4. When the countdown terminates, the selected cycle starts.

5.2 Cancelling a programme

5.2.1

Reset

To cancel a programme that has already started:
1. Press button S1 (Start) for at least 3 seconds
2. LED LD1 flashes
3. Salt/Rinse-aid LEDs light up: the programme is cancelled and the appliance returns to preselection
mode.
4. Select the new programme.
5.2.2

Interruption of a programme (pause)

If the knob is turned to position "0", the washing programme interrupts.
Turning the knob to the position corresponding to the programme in progress or to any other position,
the appliance switches on again and the programme previously chosen starts from the point at which it
was interrupted.
If the door is opened, the appliance remains on (the power loads are deactivated).
The Option LED remains on.
Closing the door the programme starts, after a brief delay, from the point at which it was interrupted.
Important! If the appliance is switched off or if the door is opened for more than 30 seconds during
the drying phase, the cycle is considered to have been terminated after the regeneration phase;
when the appliance is switched on again, it returns to programme selection mode.

5.3 Power failure

The Power Failure function maintains the information relative to the cycle status even in the even of a
power outage; when the power supply is restored, the cycle resumes from the point at which it was
interrupted.
If the power failure occurs during the drying phase, the cycle is considered to have been terminated after the
regeneration phase.
The Power Failure has been defined in the following way:
When a Power Fail occurs, all loads switch off simultaneously to enable to save the data in
EEPROM, through the energy stored in the supply condenser of the control board, and when the
power is restored, the cycle restarts from the point at which it was interrupted.
SOI/TD 2004-11 PR
7/
26
599 36 44-44