12.3 Functional testing cycle
This is an abbreviated washing programme (50 min) which allows the Service Engineer to test all the
functions that comprise a traditional washing cycle; in effect, the system simulates a normal cycle.
12.3.1 Selecting the cycle
To activate the function:
1. Press and hold down button S1.
2. turn the knob anti-clockwise till Position 5.
the LEDs LD0 and LD1 flash.
release button S1.
3. Turn the knob till Position 3
press button S1.
the programme starts: the programme behaves as in a normal cycle; the PAUSE and CANCEL options
are accessible.
12.3.2 Cycle phases
Phase
Water fill, Turbo activation
Continuous washing, dispenser
opening
Drain
Water fill
Continuous washing
Drain
Water fill
Controlled washing 2600rpm,
heating at 60°C
Controlled washing 2600rpm,
maintaining at 60°C
N.B.: At the beginning of the subsequent programme (i.e. after the test cycle), the resins are washed. The
overall duration of the test cycle is about 50 minutes.
12.4 Exiting Service and User modes
To exit these modes, turn the knob to OFF position and switch the appliance off or wait 60 seconds:
the LEDs light up and the appliance returns to selection mode.