Test Equipment Required for Alignment
No.
Test Equipment
1
Standard Signal Generator
(SSG)
2
Power Meter
3
Deviation Meter
4
Digital Volt Meter
(DVM)
5
Oscilloscope
6
High sensitivity
Frequency Counter
7
Ammeter
8
AF Volt Meter
(AF VTVM)
9
Audio Generator (AG)
10
Distortion Meter
11
Voltmeter
12
4Ω Dummy Load
13
Regulated Power Supply
Caution
Since the RX AF output is a BTL output, there is a DC
Component. Isolate this with a capacitor or transformer as
shown in the figure.
MIC connector
(Front view)
1
2
12
11
3
4
10
9
5
8
6
7
1 : SB
2 : HOOK
3 : MICG
4 : MIC
5 : Earth
6 : TRD
7 : NC
8 : DM
9 : BLC
10 : PTT
11 : NC
12 : NC
ADJUSTMENT
Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measurement Capability
Frequency Range
Measuring Range
Accuracy
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Measuring Range
Input Impedance
Test cable for microphone input
E30-3313-08
2 : HOOK (GRY)
To AG
4 : MIC (WHT)
AF VTVM
3 : MICG (Shield)
Cut
TK-790/
Major Specifications
100 to 200MHz.
Frequency modulation and external modulation.
0.1µV to greater than 1mV.
50Ω.
100 to 200MHz or more.
Vicinity of 200W.
148 to 174MHz.
1 to 20V DC.
High input impedance for minimum circuit loading.
DC through 30MHz.
10Hz to 200MHz.
0.2ppm or less.
30A.
50Hz to 10kHz.
3mV to 3V.
50Hz to 5kHz or more.
0 to 1V.
3% or less at 1kHz.
50mV to 10Vrms.
10 to 1.5V DC or less.
50kΩ/V or greater.
Approx. 4Ω 30W.
(Adjustable from 9 to 17V, 30A).
Useful if ammeter equipped.
Test cable for speaker output
10 : PTT (BLU)
PTT SW
5 : PTT (BLK)
(
B
)
/H
(
B
)
67