Chapter 7. Occurrence And Handling Of Alarm, Loss, Motion; Alarm Occurrence Conditions; Alarm Release; Screen Conversion - Samsung SDM-160 User Manual

Digital multiplexer
Table of Contents

Advertisement

Digital Multiplexer

Chapter 7. Occurrence and handling of alarm, loss, motion

1.Alarm occurrence conditions

The following events occur if alarm occurs since the sensor is connected to the alarm input terminal
on the backside:
1) Warning sounds (if buzzer turns "ON").
2) Alarm information (date and time when alarm occurs) is recorded on the alarm list.
3) "RESET" LED blinks.
4) The alarm output (HOT, COLD) signal is active for the alarm hold time.
5) The record times of the channel that alarm occurs increase.
6) Screen is converted to the channel that alarm occurs.
7) Display character of "ALARM" or "A" appears (if the alarm information turns "ON").
8) Alarm continues for the alarm hold time that is set in the program mode.

2.Alarm release

The alarm status is released if pressing the "RESET" button when alarm occurs or the alarm holds time set-
ting passes.

3.Screen conversion

1) Single alarm: The occurrence channel appears on monitor in the form of full screen.
2) Multiple alarm: Display the occurrence channel as the division screen depending on the occurrence num-

4.Alarm record

Perform the alarm weight value record in the chapter 6.

5.Alarm signal standard

You can view record output when alarm occurs during record.
For example, if record status have the following conditions:
¥ Currently perform record in the TLV mode on the time lapse VCR.
¥ Set the "REC TYPE" to "NOR" in the "5. ALARM SET" of the "program mode".
The record output until release after the alarm occurs is as follows:
VCR TRIG
Record output
operation
ALARM OUTPUT
Output
ALARM RESET
Output
Alarm holds time: Time performing alarm operation after recognizing alarm.
bers.
Example) When alarm occurs at the same time in CH1, CH10, CH14 Display CH1, CH10, CH14 on the 4-
division screen.
TLV operation
Alarm occurrence
TRIG override
NOR operation
TLV
More than 150ms
Alarm reset
7-1