Parameter
Value range
Temperature
Pt 0.00385055
•
coefficient
Pt 0.003916
•
Pt 0.003902
•
Pt 0.00392
•
Pt 0.00385
•
Ni 0.00618
•
Ni 0.00672
•
LG-Ni 0.005
•
Cu 0.00427
•
Temperature
Degrees Celsius
•
unit
Degrees Fahrenheit
•
Kelvin
•
Reference
No reference channel mode
•
junction
4
Reference channel of the
•
module
Internal reference junction
•
Reference channel of
•
group 0 to 3
Fixed reference
•
temperature
Smoothing
None
•
Weak
•
Medium
•
Strong
•
Interference
60 Hz
•
frequency
50 Hz
•
suppression
3
16.6 Hz
•
Scalable
Disable
•
measuring
Enable
•
range
Measuring
2 decimal places
•
range
3 decimal places
•
resolution
Measuring
Value within the nominal
•
range center
range of the measuring
range
Conductor
0 to 50000 mΩ
resistance
5
Analog input module AI 4xRTD/TC 2-/3-/4-wire HF (6ES7134-6JD00-0CA1)
Manual, 02/2014, A5E03573289-AD
Default
Pt 0.00385055
Degrees Celsius
No reference
channel mode
None
50 Hz
2
Disable
2 decimal places
0
0
Parameters/address space
Reconfiguration
Scope with configuration
in RUN
STEP 7 (TIA Portal)
GSD file
PROFINET IO
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
Yes
Channel
4.2 Parameters
software, e.g.,
GSD file
PROFIBUS DP
Channel
Module
Channel
Channel
Channel
-
-
-
-
21