4.10 Extension [4]
Extension Name
Specifies the name of the extension. As for the available characters, refer to the character code table
described in section 3.2.1 Installing and Starting KX-TDA Maintenance Console.
Default
Not stored.
Value Range
Max. 20 characters
Feature Guide References
None
Outgoing Preferred Line
Selects the line to be seized after going off-hook to make a call.
Default
ICM
Value Range
No Line: No line is seized.
Idle: An idle CO line is seized automatically from the programmed CO line groups.
ICM: An extension line is seized.
F-1–F-36: A CO line programmed for a flexible CO button (F-1–F-36) is seized. A flexible CO button
customized as a Single-CO, Group-CO, Loop-CO, or G-DN button must be selected.
Programming Guide References
4.10.5 Wired Extension—Flexible Key [4-1-4]
Feature Guide References
1.5.5.2 Line Preference—Outgoing
Incoming Preferred Line
Selects the line on which an incoming call is answered after going off-hook.
Default
Ringing Line
Value Range
No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call.
Ringing Line: The longest ringing call is selected.
F-1–F-36: The call arriving at a flexible CO button (F-1–F-36) is selected. A flexible CO button customized
as a Single-CO, Group-CO, Loop-CO, or G-DN button must be selected.
Programming Guide References
4.10.5 Wired Extension—Flexible Key [4-1-4]